a. Limit Setting of Ø35 Tubular motor
OPEN LIMIT
  Adjust screw B if shutter open clockwise. (See fig. e)
  Adjust screw A if shutter open counter-clockwise. (See fig. d)
1. Turn the screw clockwise to increase open limit.
2. Turn the screw counter-clockwise to decrease open limit.
   
CLOSE LIMIT
  Adjust screw B if shutter close clockwise. (See fig. f)
  Adjust screw A if shutter close counter-clockwise. (See fig. g)
1. Turn the screw clockwise to increase close limit.
2. Turn the screw counter clockwise to decrease close limit.

 

b. Limit Setting of Ø45 Tubular motor
OPEN LIMIT
  Adjust screw B if shutter open clockwise. (See fig. e)
  Adjust screw A if shutter open counter clockwise. (See fig. d)
1. Turn the screw clockwise to decrease open limit.
2. Turn the screw anti-clockwise to increase open limit.
   
CLOSE LIMIT
  Adjust screw B if shutter close in clockwise. (See fig. f)
  Adjust screw A if shutter close in anti-clockwise. (See fig. g)
1. Turn the screw clockwise to decrease close limit.
2. Turn the screw anti-clockwise to increase limit.