| a.
Limit Setting of Ø35 Tubular motor |
 |
| OPEN LIMIT |
| |
Adjust screw B if shutter open clockwise. (See fig. e) |
| |
Adjust screw A if shutter open counter-clockwise. (See fig.
d) |
| 1. |
Turn the screw clockwise to increase open limit. |
| 2. |
Turn the screw counter-clockwise to decrease open limit. |
| |
|
| CLOSE LIMIT |
| |
Adjust screw B if shutter close clockwise. (See fig. f) |
| |
Adjust screw A if shutter close counter-clockwise. (See
fig. g) |
| 1. |
Turn the screw clockwise to increase close limit. |
| 2. |
Turn the screw counter clockwise to decrease close limit. |
| b.
Limit Setting of Ø45 Tubular motor |
|
| OPEN LIMIT |
| |
Adjust screw B if shutter open clockwise. (See fig. e) |
| |
Adjust screw A if shutter open counter clockwise. (See fig.
d) |
| 1. |
Turn the screw clockwise to decrease open limit. |
| 2. |
Turn the screw anti-clockwise to increase open limit. |
| |
|
| CLOSE LIMIT |
| |
Adjust screw B if shutter close in clockwise. (See fig.
f) |
| |
Adjust screw A if shutter close in anti-clockwise. (See
fig. g) |
| 1. |
Turn the screw clockwise to decrease close limit. |
| 2. |
Turn the screw anti-clockwise to increase limit. |
| |
|